Vertiv™ SmartIT for Enterprise - Pre-integrated AI rack infrastructure for NVIDIA Blackwell-based NVL72 configurations
Enterprise AI requires power, cooling, and rack infrastructure that many existing environments were not designed to support. Vertiv™ SmartIT is a pre-integrated, AI infrastructure solution for NVIDIA GB300 Blackwell-based NVL72 compute, combining Vertiv power, cooling, rack infrastructure, and commissioning into one factory-tested package ordered as one solution and delivered as one unit.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
Vertiv™ SmartIT for Enterprise - Pre-integrated AI rack infrastructure for NVIDIA Blackwell-based NVL72 configurations
Enterprise AI requires power, cooling, and rack infrastructure that many existing environments were not designed to support. Vertiv™ SmartIT is a pre-integrated, AI infrastructure solution for NVIDIA GB300 Blackwell-based NVL72 compute, combining Vertiv power, cooling, rack infrastructure, and commissioning into one factory-tested package ordered as one solution and delivered as one unit.
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
Benefits
- FULL POWER AND THERMAL CHAIN: Vertiv™ SmartIT integrates rack-level power, cooling, and enclosure infrastructure into a factory-tested package designed for NVIDIA DGX GB300 Blackwell-based NVL72 compute.
- FACTORY-INTEGRATED AND TESTED: Each module arrives pre-integrated and pre-validated. Commissioning scope covers facility-level connections only, reducing coordination complexity and supporting faster time-to-value.
- NVIDIA and OCP-COMPLIANT ARCHITECTURE: Uses Vertiv™ Open Rack for NVIDIA MGX infrastructure for NVIDIA Blackwell-based NVL72-class architecture and OCP-compliant rack deployment in defined configurations.
Features
- CONFIGURABLE RACK ENCLOSURES: Support rack and storage rack configurations are available to meet deployment requirements.
- VERTIV™ POWERDIRECT 3000 DC POWER SHELVES (33 kW): Vertiv™ PowerDirect provides rack-level DC power conversion for compute racks, with two 33 kW shelves per support rack.
- IN-RACK XDU (DIRECT-TO-CHIP LIQUID COOLING): Vertiv™ CoolChip CDU 121 provides 121 kW direct-to-chip liquid cooling per unit, with three units included in the package.
- RDHX (ACTIVE REAR DOOR HEAT EXCHANGER): Vertiv™ Liebert® DCD 47kW rear door heat exchangers provide supplemental air cooling.
- IN-RACK MANIFOLD: Blind mate connection for coolant distribution designed to reduce maintenance complexity and leak risk within the rack envelope.
- INTEGRATED LEAK DETECTION: Drip tray and manifold sensors connect through Vertiv™ Avocent® ACS 804 to support continuous leak monitoring and site-defined fault-response.
- NORTHBOUND COMMUNICATION: Redfish, SNMP, and Modbus TCP/RS485 for integration into existing data center management platforms.
- NVIDIA PLATFORM VALIDATION: Validated for NVIDIA DGX GB300 Blackwell-based NVL72 platforms with NVIDIA Grace and 72 NVIDIA Blackwell GPUs per rack.
Find Your Area Contact
Change
Specifications
| Parameter | Specification |
|---|---|
|
Solution footprint |
Integrated package |
|
Power Capacity per compute rack |
120–142 kW |
|
Liquid cooling capacity |
2× 121kW = 242kW N+1 (direct-to-chip) |
|
Supplemental air cooling |
3× 47kW = 141kW (active rear door) |
|
Total module cooling |
441kW |
|
UPS efficiency |
Up to 97.5% double-conversion |
|
Rack standard |
OCP-compliant MGX architecture |
From one rack to many
Expand AI compute in modular steps. Same architecture. Same validation. Nothing redesigned. Each module ships pre-integrated and factory-tested against the same specification as the initial deployment. Integration, power infrastructure, and cooling design remain consistent across all configurations.
Support Rack (IRM692-362-VQE0M-N00)
Provides support for network switches, leak detection, and houses CDU and Power Shelves. Pairs seamlessly with the AI compute rack to enable a complete, deployment-ready infrastructure.
Storage Rack (IRM692-362-00E00-N00)
Purpose-built for storage deployments, featuring two 60A 3-phase PDUs with 69 kVA total capacity for reliable power distribution. Complements the AI compute rack to deliver a unified, high-density solution.
| Components | Function | Support Rack | Storage Rack |
|---|---|---|---|
| RACK INFRASTRUCTURE | |||
|
Vertiv™ Open Rack for NVIDIA MGX |
MGX-compliant enclosures for Blackwell-based NVL72 architecture |
1 |
1 |
| POWER TRAIN | |||
|
Vertiv™ PowerDirect Shelf (33kW shelves, 50 VDC) |
Rack-level DC power conversion (Compute racks) |
2 |
— |
|
Vertiv™ Liebert® APM2 UPS + Battery Cabinet |
Modular UPS protection; up to 97.5% efficiency |
Optional |
Optional |
|
Vertiv™ rPDU (Switched, outlet-level monitored) |
Intelligent AC power distribution (Storage rack) |
— |
2 |
|
Vertiv™ PowerIT Rack Transfer Switch |
Automatic source transfer for single-corded devices |
2 |
2 |
| THERMAL CHAIN | |||
|
Piping, valve & actuator assemblies |
Facility water loop isolation and flow control |
Comes with support rack |
— |
|
Vertiv™ CoolChip CDU 121 |
Direct-to-chip liquid cooling (121kW per unit) |
3 |
— |
|
Vertiv™ Liebert® DCD47 Rear Door Heat Exchanger |
Supplemental air cooling; 47kW room-neutral per rack |
1 |
1 |
| MONITORING | |||
|
Vertiv™ Avocent® ACS 804 |
Leak detection and response gateway |
1 |
— |
|
Vertiv™ Avocent® RM1048P Rack Manager |
Rack-level device access and management |
2 |
— |
| SERVICES | |||
|
Services & warranty |
Installation, commissioning—including flush and fill—and project management |
Included |
Included |
*NVIDIA DGX Blackwell-based NVL72 provided by NVIDIA
Scope boundary: Vertiv™ SmartIT covers the integrated package. Facility-level power distribution, utility connections, and building infrastructure are outside the solution boundary and addressed through standard site preparation guidance.