Albér BDSU
The data center monitoring system provides detailed battery information, allowing for cost savings by optimizing useful battery life. Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems, you can continue to utilize your batteries longer and with confidence by knowing their true internal condition.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Data Center/Colocation/Hosting
- Government
- Nuclear Power
- Power Generation
- Power/Gas Transmission and Distribution
- Telecom
Albér BDSU
The data center monitoring system provides detailed battery information, allowing for cost savings by optimizing useful battery life. Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems, you can continue to utilize your batteries longer and with confidence by knowing their true internal condition.
- Data Center/Colocation/Hosting
- Government
- Nuclear Power
- Power Generation
- Power/Gas Transmission and Distribution
- Telecom
Specifications
The data center monitoring system provides detailed battery information, allowing for cost savings by optimizing useful battery life. Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems, you can continue to utilize your batteries longer and with confidence by knowing their true internal condition.
Benefits
-
Flexibility
- Windows-based software or optional web-based software for real-time viewing, automatic data collection, data analysis, and report generation.
- Industry standard MODBUS protocol interfaces to third party building management systems via Ethernet.
- Optional TCP/IP interface for network or Internet communication via MODBUS or SNMP. Higher Availability
- Scans pertinent battery parameters every 4 seconds, including total voltage, cell voltage, current and temperature.
- Automatic proactive internal DC resistance tests.
- Discharges are automatically detected and data saved for retrieval and playback.
- Trend analysis provides the ability to analyze performance and aid in trouble shooting.
- Maintenance by the Liebert Services local, factory-trained Customer Engineers promotes proper operation and longer service life for UPS and batteries. Lowest Total Cost of Ownership
- Optimizes useful battery life -- Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems, you can continue to utilize your batteries longer and with confidence by knowing their true internal condition.
- Provides the data for a battery replacement program, only replacing batteries that are identified as failing.
Features
- Automatic scheduled testing of internal resistance, intertier/inter-row and mid string disconnect switch connection measurements.
- Communicates via two Liebert® Intellislot ports for remote or local protocols, such as MODBUS, SNMP, SMTP, SMS, HTTP and others.
- Self calibrating.
- Embedded Web server for viewing battery data via Web browsers and embedded email manager for delivery of alerts and battery data on a defined priority to service technicians.
- Compact 2U, 19" rack mount, Control Module and 1U Battery Module.