NetSure 7000 Series for Access / Edge
NetSure 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. The high operating temperature (up to 900 amps at +65°C) in conjunction with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
Guadar este produto no seu dashboard
Você pode guardar este produto no seu dashboard para ve-lo depois. Você pode elimina-lo com facilidade do seu dashboard quando você já no quer ve-lo lá.
Please login or create an account to save this for later
- Telecomunicação
NetSure 7000 Series for Access / Edge
NetSure 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. The high operating temperature (up to 900 amps at +65°C) in conjunction with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
- Telecomunicação
Especificações
NetSure 7100 Compact 582137100101-106 (19")
|
||||||||
---|---|---|---|---|---|---|---|---|
24 kW | 500 A | -48 VDC | 100 to 240 VAC | Rack or cabinet mount | 6-8U (10.5” to 14") | 19” | 15.6” to 16.6" | 42 to 54 lbs |
See more product information | ||||||||
NetSure 7100 Compact 582127000600-901 (23")
|
||||||||
28.8 too 43.2 kW | 600 to 900 A | -48 VDC | 208 to 240 VAC | Cabinet mount | 10-11U (17.5” to 19.2") | 23” | 20.4” | 125 to 138 lbs |
See more product information |
Vantagens
Recursos
- Rectifier User Manual UM1R483500E3
- NetSure DC Converter Module UM1C48583750P4
- SM-TEMP User Manual UM547490
- UM1M830BNA NCU Controller User Manual
- Rectifier User Manual UM1R483500E3
- NetSure X701 Installation Manual IM10025975
- Vertiv™ NetSure™ 7100 -48V DC Power System User Manual UM582127000900.pdf
- Vertiv™ Netsure™ 7100 -48V DC Power System Installation Manual IM582127000900
- eSure™ Rectifier User Manual 1R243000
- eSure +27 VDC Bullet Converter Installation and User Manual UM60147273
- DC Generator Input Landing Kit Installation Manual IM10067484
- Mounting Kit for NetSure 7100 Compact Systems Installation Manual IM60019000
- +27 VDC Vertiv™ eSure™ Bullet Converter Mounting Bracker Kit IM60171745
- DC Generator Input Circuit Breaker Kit Installation Manual IM60141027
*Para ver downloads específicos de modelos, é necessário acessar a página de produto específica do modelo, selecionando o nome do modelo na tabela de especificações acima.