Vertiv™ CoolPhase Row, Row Based Cooling, 30-40kW
Vertiv CoolPhase Row is seamlessly integrated within the row of data center racks to optimize space utilization. It offers advanced temperature control 24/7/365, using inverter-driven compressors and variable speed fans. Together, they adjust cooling output to match dynamic heat loads, boosting energy efficiency and reducing operational costs. The latest design incorporates a refreshed look and standardized models, ensuring compatibility with global data center standards.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
Vertiv™ CoolPhase Row, Row Based Cooling, 30-40kW
Vertiv CoolPhase Row is seamlessly integrated within the row of data center racks to optimize space utilization. It offers advanced temperature control 24/7/365, using inverter-driven compressors and variable speed fans. Together, they adjust cooling output to match dynamic heat loads, boosting energy efficiency and reducing operational costs. The latest design incorporates a refreshed look and standardized models, ensuring compatibility with global data center standards.
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
Specifications
|
Vertiv™ CoolPhase Row, Row Based Cooling, 30kW
|
||||
|---|---|---|---|---|
| 102,000 BTUH (30kW) | 3900 CFM | 43.3in | 11.8in | 47.2in |
| See more product information | ||||
|
Vertiv™ CoolPhase Row, Row Based Cooling, 40kW
|
||||
| 136,000 BTUH (40kW) | 5700 CFM | 43.3in | 23.6in | 47.2in |
| See more product information |
Benefits
Features
- Vertiv™ CoolPhase Row 600 mm and 300 mm Wide - Installer Guide - NA - EN - R1125
- Vertiv™ CoolPhase Condensing Unit 28-35kW - Installer User Guide - NA - EN - R0126
- Vertiv™ CoolPhase Row - System Design Catalog - NA - EN - R1125
- Vertiv™ CoolPhase Row CRD030 and CRD040 - Submittals Addendum - NA - EN - R1225
- Vertiv™ CoolPhase Row and Condensing Unit Power Meter - Quick Installation Guide - NA - EN - R1125
- Vertiv™ CoolPhase Row CRD030 - Unpacking Instructions - NA - EN - R1125
- Vertiv™ CoolPhase Row CRD040 - Unpacking Instructions - NA - EN - R1125
- Vertiv™ CoolPhase Condensing Unit 21-35kW - Unpacking Instructions - NA - EN - R0725
- Vertiv™ CoolPhase Condensing Unit 21-35kW - Hail Guard Kit - Quick Installation Guide - NA - EN - R0725
- Vertiv™ CoolPhase Condensing Unit 21-35kW - Handling Instructions - NA - EN - R0725
- Vertiv™ CoolPhase Row 300mm - Thermal Management Guide - NA - EN - R1125
- Vertiv™ CoolPhase Row 600mm - Thermal Management Guide - NA - EN - R1125
- Vertiv™ Liebert® iCOM™ - Installer User Guide
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.