Liebert® XDU60 Coolant Distribution Unit
Designed to remove barriers to liquid cooling in an air-cooled, environment the Liebert® XDU060 Coolant Distribution Unit is a liquid-to-fluid exchanger for chip cooling applications that offers easy, cost-effective deployment in any data center. The Liebert® XDU operates without facilities water and provides an isolated water secondary circuit allowing you to tap into the benefits of water-cooled doors to more efficiently support higher rack densities without incurring the costs of major infrastructure changes.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Data Center/Colocation/Hosting
- Education
- Healthcare
- Government
- Retail and Wholesale
Liebert® XDU60 Coolant Distribution Unit
Designed to remove barriers to liquid cooling in an air-cooled, environment the Liebert® XDU060 Coolant Distribution Unit is a liquid-to-fluid exchanger for chip cooling applications that offers easy, cost-effective deployment in any data center. The Liebert® XDU operates without facilities water and provides an isolated water secondary circuit allowing you to tap into the benefits of water-cooled doors to more efficiently support higher rack densities without incurring the costs of major infrastructure changes.
- Data Center/Colocation/Hosting
- Education
- Healthcare
- Government
- Retail and Wholesale
Benefits
Features
Specifications
With its row-based format and 60 kW+ of heat rejection, the Liebert XDU can handle the thermal needs of today’s advanced hardware without taking up valuable rack space. The fully-enclosed system operates with minimal water volume and is filled at the time of installation. It can be mounted adjacent to or nearby a cabinet of water-cooled servers to channel rejected hot air to the right location in the data center space where it can be effectively handled by existing air-cooled units, coordinating with the facility’s current cooling configuration. The XDU features the option of hose piping, an integrated filter to ensure water quality, and a redundant pump design for reliability. Variable speed drive (VSD) controls, EC fans, and state-of-the-art Liebert iCOM™ Controls allow you to set the flow rate based on facility conditions and automatically match supply water temperature to the load for highly efficient operation.
- Product Specifications
- Net Sensible Nominal Capacity kBtuh[kW]*
- 63.0 kW
- Nominal Airflow Data Center Air (CFM, m3/h)
- 5650 m3/h (3325 CFM)
- Net Sensible Nominal Capacity kBtuh[kW]*
- 63.0 kW
- Nominal Airflow Data Center Air (CFM, m3/H)
- 5650 m3/h (3325 CFM)
- Input Voltage (V/Phase/Frequency Hz)
- 208V, 3PH, 60Hz
- Controls and Monitoring
- Color touch screen display
- Key Components
- Redundant pump design, variable-speed pump controls, and electronically commutated (EC) fans
- Physical Characteristics
- Weight
- 847 lbs
- Weight
- 384 kgs
- Height
- 42U, 78 3/4 in
- Height
- 2000 mm
- Width
- 23 5/8 in
- Width
- 600 mm
- Depth
- 46 1/4 in
- Depth
- 1175 mm
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.