End-to-end systems for next-gen AI
Discover how Vertiv delivers end-to-end systems and services engineered for AI at scale and multiple compute generations ahead.
Learn moreRetrofit designs
Whether testing a new AI model or upgrading on-premises infrastructure, these ready-to-order retrofit designs streamline your next deployment.
<
Quotable designs optimized for retrofits
| Total rack density | Total rack count | Total deployment size | Design ID | Cooling technology | ||
|---|---|---|---|---|---|---|
| NA | EMEA | ASIA | ||||
| 40kW | 4 | 160kW | 4X160R |
N/A | 4X160RA | Air |
| 70kW | 1 | 70kW | 1L88R |
1L88RE |
1L88RA |
Liquid + Air |
| 80kW | 1 | 80kW | 1X80 |
1X80E | 1X80A | Air |
| 100kW | 1 | 100kW | 1L100R |
1L100RE |
1L100RA |
Liquid + Air |
| 100kW | 4 | 400kW | 4L400R |
N/A | 4L400RA | Liquid + Air |
| 100kW | 4 | 400kW | 4XL400 |
4XL400E |
4XL400A |
Liquid + Air |
| 100kW | 5 | 500kW | 5L500 |
5L500E |
5L500A |
Liquid + Air |
| 100kW | 12 | 1200kW | 12XL1200 |
12XL1200E |
12XL1200A |
Liquid + Air |
| 100kW | 14 | 1400kW | 14L1400 |
14L1400E |
14L1400A |
Liquid + Air |
| 115kW | 1 | 132kW | N/A | 1XL115E |
N/A | Liquid + Air |
Reference designs
Vertiv's reference designs give you a clear starting point for AI data center builds and simplify integration for high-density workloads.
Design for new builds
| Total rack density | Total rack count | Total deployment size | Ref. GPU type | Design ID | Cooling technology | ||
|---|---|---|---|---|---|---|---|
| NA | EMEA | ASIA | |||||
| 20kW | 18 | 360kW | H100 | RD002 |
RD002E |
RD002A |
Air |
| 40kW | 10 | 360kW | H100 | RD003 |
RD003E |
RD003A |
Air |
| 142kW | 13 | 1.3MW | GB300 | RD018 |
RD018E |
RD018A | Liquid + Air |
| 142kW | 72 | 5.2MW | GB300 | RD019 |
RD019E |
RD019A | Liquid + Air |
| 130kW | 108 | 7MW | GB200 | RD020 |
RD020E | RD020A | Liquid + Air |
| 130kW | 18 | 1.2MW | GB200 | RD021 |
RD021E | RD021A | Liquid + Air |
| 58kW | 10 | 500kW | B200 | RD024 |
RD024E | RD024A | Air |
| 142kW | 40 | 2.5MW | GB300 | RD027 |
RD027E | RD027A |
Liquid + Air |
| 142kW | 64 | 5MW | GB300 | RD028 |
RD028E | RD028A |
Liquid + Air |
| 142kW | 80 | 5MW | GB300 | RD029 |
RD029E | RD029A |
Liquid + Air |
| 142kW | 128 | 10MW | GB300 | RD030 |
RD030E | RD030A |
Liquid + Air |
Vertiv design principles
Explore how implementing these principles can optimize the strategic deployment of AI workloads.
Spotlight
Converged Physical Infrastructure for NVIDIA Vera Rubin DSX AI Factory Designs
Fully virtualized AI factory models accelerate deployment
Learn moreAdvanced energy optimization solutions for data centers
Overcome today’s energy constraints and deploy optimized gigawatt-scale AI centers with on-site energy solutions
Learn more
Customer Spotlight: Vertiv and Compass Datacenters
Vertiv and Compass Datacenters partner to deploy Vertiv™ SmartRun for a flexible, consistent whitespace infrastructure solution to speed up data hall readiness.
Read more