Design
Apply Vertiv’s design principles and access validated reference designs to optimize AI workload deployment.
Retrofit designs
Whether testing a new AI model or upgrading on-premises infrastructure, these ready-to-order retrofit designs streamline your next deployment.
<
Quotable designs optimized for retrofits
| Total rack density | Total rack count | Total deployment size | Design ID | Cooling technology | ||
|---|---|---|---|---|---|---|
| NA | EMEA | ASIA | ||||
| 40kW | 4 | 160kW | 4X160R |
N/A | 4X160RA | Air |
| 70kW | 1 | 70kW | 1L88R |
1L88RE |
1L88RA |
Liquid + Air |
| 80kW | 1 | 80kW | 1X80 |
1X80E | 1X80A | Air |
| 100kW | 1 | 100kW | 1L100R |
1L100RE |
1L100RA |
Liquid + Air |
| 100kW | 4 | 400kW | 4L400R |
N/A | 4L400RA | Liquid + Air |
| 100kW | 4 | 400kW | 4XL400 |
4XL400E |
4XL400A |
Liquid + Air |
| 100kW | 5 | 500kW | 5L500 |
5L500E |
5L500A |
Liquid + Air |
| 100kW | 12 | 1200kW | 12XL1200 |
12XL1200E |
12XL1200A |
Liquid + Air |
| 100kW | 14 | 1400kW | 14L1400 |
14L1400E |
14L1400A |
Liquid + Air |
| 115kW | 1 | 132kW | N/A | 1XL115E |
N/A | Liquid + Air |
Reference designs
Vertiv's reference designs give you a clear starting point for AI data center builds and simplify integration for high-density workloads.
Design for new builds
| Total rack density | Total rack count | Total deployment size | Ref. GPU type | Design ID | Cooling technology | ||
|---|---|---|---|---|---|---|---|
| NA | EMEA | ASIA | |||||
| 20kW | 18 | 360kW | H100 | RD002 |
RD002E |
RD002A |
Air |
| 40kW | 10 | 360kW | H100 | RD003 |
RD003E |
RD003A |
Air |
| 130kW | 108 | 7MW | GB200 | RD020 |
RD020E | RD020A | Liquid + Air |
| 130kW | 18 | 1.2MW | GB200 | RD021 |
RD021E | RD021A | Liquid + Air |
| 58kW | 10 | 500kW | B200 | RD024 |
RD024E | RD024A | Air |
| 142kW | 40 | 2.5MW | GB300 | RD027 |
RD027E | RD027A | Liquid + Air |
| 142kW | 64 | 5MW | GB300 | RD028 |
RD028E | RD028A | Liquid + Air |
| 142kW | 80 | 5MW | GB300 | RD029 |
RD029E | RD029A | Liquid + Air |
| 142kW | 128 | 10MW | GB300 | RD030 |
RD030E | RD030A | Liquid + Air |
AI solutions
Accelerate your AI infrastructure with end-to-end solutions engineered for density, speed, and lifecycle efficiency.
Adding Vertiv expertise to the NVIDIA Partner Network
Vertiv and NVIDIA collaborated to develop a unique AI cooling solution for the COOLERCHIPS program and formalized our partnership when Vertiv joined the NVIDIA Partner Network. NVIDIA’s cutting-edge platforms need advanced infrastructure solutions. AI deployments can count on Vertiv’s leadership in power and cooling to keep their AI running no matter the cluster size.
Spotlight
Learn about the gigawatt-scale, flexible AI infrastructure with NVIDIA Omniverse DSX Blueprint
Spotlight
See how Vertiv and Caterpillar and Solar Turbines combine to deliver Bring-Your-Own-Power & Cooling (BYOP&C) for grid-to-chip resilient, on-site power generation solutions.