Liebert® XDU1350 Coolant Distribution Unit
Designed to remove barriers to liquid cooling in an air-cooled environment, the Liebert® XDU1350 Coolant Distribution Unit is liquid to liquid heat exchanger for chip & rear door cooling applications that offers easy, cost-effective deployment in any data center. The Liebert® XDU operates without facilities water, allowing you to tap into the benefits of water-cooled servers to more efficiently support higher rack densities without incurring the costs of major infrastructure changes.
將此產品儲存到您的控制板
您已成功儲存此產品以便稍後查看;如需取消,可在控制板移除此產品。
請登錄或創建新帳戶以儲存此產品/服務
- Data Center/Colocation/Hosting
- Education
- Healthcare
- Government
- Retail and Wholesale
Liebert® XDU1350 Coolant Distribution Unit
Designed to remove barriers to liquid cooling in an air-cooled environment, the Liebert® XDU1350 Coolant Distribution Unit is liquid to liquid heat exchanger for chip & rear door cooling applications that offers easy, cost-effective deployment in any data center. The Liebert® XDU operates without facilities water, allowing you to tap into the benefits of water-cooled servers to more efficiently support higher rack densities without incurring the costs of major infrastructure changes.
- Data Center/Colocation/Hosting
- Education
- Healthcare
- Government
- Retail and Wholesale
客戶價值
特性
技術規格
The Vertiv™ XDU delivers flexibility to support rear door heat exchangers or direct contact liquid cooling. The Vertiv XDU’s compact footprint allows for end of row or perimeter placement. However and wherever you incorporate the Vertiv XDU, you can easily distribute coolant to efficiently manage power-dense hot spots up to 1,368 KW. Redundant pumps and power inputs ensure the Vertiv XDU is always doing its job while smart settings and teaming options ensure the precise temperature, flow rate, and pressure are continuously maintained to cool your IT environment as effectively and efficiently as possible. The stainless-steel wetted material provides peace over corrosion concerns. A built-in 50-micro filtration unit works around the clock to keep the secondary fluid network free from debris and contaminants that could hinder performance. Remote Monitoring is available through HTTP, SNMP, RS-485 Modbus, Modbus IP communications. The integrated controller provides accurate performance setpoints, flow control and monitoring with integrated leak detection and operational alarm features to help maintain system and efficiency.
- Technical Specifications
- 淨顯熱額定容量 kBtuh [kW]*
- 1368 kW at 7.2°F (4°C)
- 額定氣流資料中心空氣 (CFM, m3/H)
- N/A
- 淨顯熱額定容量 kBtuh [kW]*
- 1368 kW at 7.2 F (4 C): Secondary Circuit flow rate at 320 GPM (1200 l/m) at 35.4 psi ( 2.44 bar) external ΔP
- 輸入電壓(V/相數/頻率 Hz)
- 480 V ,3PH, 60Hz
- 控制與監控
- Color touch screen display
- 重要元件
- Redundant pump design with variable-speed pump controls
- Physical Characteristics
- 重量(磅/公斤)
- 1431 lbs
- 重量(磅/公斤)
- 1509 kgs
- 高度(英寸/毫米)
- 684 in
- 高度(英寸/毫米)
- 2070 mm
- 寬度(英寸/毫米)
- 35.4 in
- 寬度(英寸/毫米)
- 900 mm
- 高度(英寸/毫米)
- 48.9 in
- 高度(英寸/毫米)
- 1242 mm
- Vertiv™ Liebert® XDU 1350 - Data Sheet - English - Rev.1025
- Vertiv™ CoolChip CDU - Brochure - GL - English
- Vertiv™ XDU450 & Vertiv™ XDU1350 Brochure
- Vertiv™ CoolChip CDU Leak Detection - Data Sheet - English - rev.0326
- Vertiv™ Liebert® APM2 UPS for Mechanical Loads - Application Brief
- Vertiv™ Liquid Cooling Services - Brochure - English
- Vertiv™ Liquid Cooling Services - Data Sheet - English
*查看具體型號產品資料,請進入上方規格表具體型號的產品頁面。