BDFB-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32, enterprises, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, DateAndTime FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP,NOTIFICATION-GROUP FROM SNMPv2-CONF; bdfbMIB MODULE-IDENTITY LAST-UPDATED "201103021100Z" ORGANIZATION " Emerson Energy Systems North America (ESNA)" CONTACT-INFO " Emerson Energy Systems North America 1510 Kansas Ave. Lorain, OH 44052 USA " DESCRIPTION " Emerson Energy Systems North America(ESNA) mini-BDFB MIB. revision 1.0.0.0" ::= {enterprises 885 5 } emersonESNA OBJECT IDENTIFIER ::= { enterprises 885 } bdfbInformation OBJECT IDENTIFIER ::= { bdfbMIB 1 } bdfbStatus OBJECT IDENTIFIER ::= { bdfbMIB 2 } bdfbMeasurement OBJECT IDENTIFIER ::= { bdfbStatus 1 } bdfbTraps OBJECT IDENTIFIER ::= { bdfbMIB 3 } bdfbGroups OBJECT IDENTIFIER ::= { bdfbMIB 4 } bdfbSystemTraps OBJECT IDENTIFIER ::= { bdfbTraps 0 } bdfbBusTypeTraps OBJECT IDENTIFIER ::= { bdfbTraps 1 } bdfbBusTraps OBJECT IDENTIFIER ::= { bdfbBusTypeTraps 0 } bdfbInformationGroup OBJECT-GROUP OBJECTS { bdfbMeterPanelVersionNumber, bdfbEthernetCardVersionNumber, bdfbIdentifier } STATUS current DESCRIPTION "A collection of objects providing information to identify the BDFB plant and the version of monitoring software." ::= { bdfbGroups 1 } bdfbMeasurementGroup OBJECT-GROUP OBJECTS { bdfbAverageBusVoltage, bdfbTotalBusCurrent, bdfbAlarm, bdfbBusIndex, bdfbBusIdentifier, bdfbBusVoltage, bdfbBusCurrent, bdfbRelayIndex, bdfbRelayIdentifier, bdfbRelayStatus} STATUS current DESCRIPTION "A collection of objects providing BDFB Plant measurements and status." ::= { bdfbGroups 2 } bdfbNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { alarmTrapBDFBRelay1, alarmTrapBDFBRelay2, alarmTrapBDFBRelay3, alarmTrapBDFBRelay4, alarmTrapBDFBAuxABSFuse, alarmTrapBDFBCommFail, trapBDFBBusFuse, trapBDFBBusLowVoltage, trapBDFBBusPowerLost, trapBDFBBusHighCurrent1, trapBDFBBusHighCurrent2 } STATUS current DESCRIPTION "The notifications which indicate BDFB Plant alarms." ::= { bdfbGroups 3 } -- ******** 5.1 PLANT INFORMATION (bdfbInformation) ******** bdfbMeterPanelVersionNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Meter Panel Firmware Version Number." ::= { bdfbInformation 1} bdfbEthernetCardVersionNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet Card Firmware Version Number." ::= { bdfbInformation 2} bdfbIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Identifier String." ::= { bdfbInformation 3} -- ******** 5.2 BDFB Status (bdfbStatus) ******** -- ******** 5.2.1 BDFB MEASUREMENTS (bdfbMeasurement) ******** bdfbAverageBusVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average Bus Voltage." ::= { bdfbMeasurement 1} bdfbTotalBusCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Ttotal Bus Current." ::= { bdfbMeasurement 2} bdfbAlarm OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "An Alarm Is Active." ::= { bdfbMeasurement 3 } -- bdfbHighestSeverityLevel OBJECT-TYPE -- SYNTAX INTEGER { -- normal(0), -- minor(1), -- major(2) -- } -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The severity level is the highest active alarm level. -- Values: 0 = Normal, 1 = Minor, 2 = Major" -- ::= { bdfbMeasurement 4} -- ******** 5.2.2 BDFB Bus Status (bdfbBusTable) ******** -- ****** START OF BDFB Bus MEASUREMENT TABLE ******** bdfbBusTable OBJECT-TYPE SYNTAX SEQUENCE OF BDFBBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BDFB Bus Table." ::= { bdfbStatus 2 } bdfbBusEntry OBJECT-TYPE SYNTAX BDFBBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BDFB Bus Table Entry." INDEX { bdfbBusIndex } ::= { bdfbBusTable 1 } BDFBBusEntry ::= SEQUENCE { bdfbBusIndex INTEGER, bdfbBusIdentifier DisplayString, bdfbBusVoltage DisplayString, bdfbBusCurrent INTEGER } bdfbBusIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Bus Number." ::= { bdfbBusEntry 1 } bdfbBusIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Bus Identifier." ::= { bdfbBusEntry 2} bdfbBusVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Bus Voltage." ::= { bdfbBusEntry 3} bdfbBusCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Bus Current." ::= { bdfbBusEntry 4} -- ******** FINISH BDFB Bus MEASUREMENT TABLE ******** -- ******** 5.2.3 BDFB Relay Status (bdfbRelayTable) ******** -- ****** START OF BDFB Relay Status TABLE ******** bdfbRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF BDFBRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BDFB Relay Table." ::= { bdfbStatus 3 } bdfbRelayEntry OBJECT-TYPE SYNTAX BDFBRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BDFB Relay Table Entry." INDEX { bdfbRelayIndex } ::= { bdfbRelayTable 1 } BDFBRelayEntry ::= SEQUENCE { bdfbRelayIndex INTEGER, bdfbRelayIdentifier DisplayString, bdfbRelayStatus INTEGER } bdfbRelayIndex OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Relay Number." ::= { bdfbRelayEntry 1 } bdfbRelayIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Relay Identifier String." ::= { bdfbRelayEntry 2} bdfbRelayStatus OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "BDFB Relay Status String." ::= { bdfbRelayEntry 3} -- ******** FINISH BDFB Relay Status TABLE ******** -- ******** 5.3 BDFB SYSTEM TRAPS (bdfbTraps) ******** -- ******** 5.3.0 SYSTEM TRAPS (bdfbSystemTraps) ******** alarmTrapBDFBRelay1 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Relay 1 Typically Configured as Major Remote." --#SUMMARY "BDFB Major" --#SEVERITY MAJOR ::= { bdfbSystemTraps 1 } alarmTrapBDFBRelay2 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Relay 2 Typically Configured as Minor Remote." --#SUMMARY "BDFB Minor" --#SEVERITY MIMOR ::= { bdfbSystemTraps 2 } alarmTrapBDFBRelay3 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Relay 3 Typically Configured as Custom Remote." --#SUMMARY "BDFB Minor" --#SEVERITY MIMOR ::= { bdfbSystemTraps 3 } alarmTrapBDFBRelay4 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Relay 4 Typically Configured as Custom Remote." --#SUMMARY "BDFB Minor" --#SEVERITY MIMOR ::= { bdfbSystemTraps 4 } alarmTrapBDFBAuxABSFuse NOTIFICATION-TYPE STATUS current DESCRIPTION "Auxillary ABS Fuse Trap." --#SUMMARY "Auxillary ABS Fuse" --#SEVERITY MAJOR ::= { bdfbSystemTraps 5 } alarmTrapBDFBCommFail NOTIFICATION-TYPE STATUS current DESCRIPTION "Communication failure between ethernet card and main board." --#SUMMARY "Communication failure between ethernet card and main board" --#SEVERITY MAJOR ::= { bdfbSystemTraps 6 } -- ****** FINISH BDFB SYSTEM ALARM TRAPS ******** -- ******** 5.3.1 BDFB BUS TYPE TRAPS (bdfbBusTypeTraps) ******** -- ******** 5.3.1.0 START OF BDFB BUS ALARM TRAPS (bdfbBusTraps) ******** trapBusIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bus Identifier. This object cannot be accessed. It is used to clarify the source of a Bus trap" ::= { bdfbBusTraps 2} trapBDFBBusFuse NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Bus Fuse Alarm." --#SUMMARY "BDFB Bus Fuse Alarm" --#SEVERITY MAJOR ::= { bdfbBusTraps 3 } trapBDFBBusLowVoltage NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Bus Low Voltage Alarm." --#SUMMARY "BDFB Bus Low Voltage Alarm" --#SEVERITY MINOR ::= { bdfbBusTraps 4 } trapBDFBBusPowerLost NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Bus Power Lost Alarm." --#SUMMARY "BDFB Bus Power Lost Alarm" --#SEVERITY MAJOR ::= { bdfbBusTraps 5 } trapBDFBBusHighCurrent1 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Bus High Current 1 Alarm." --#SUMMARY "BDFB Bus High Current 1 Alarm" --#SEVERITY MINOR ::= { bdfbBusTraps 6 } trapBDFBBusHighCurrent2 NOTIFICATION-TYPE STATUS current DESCRIPTION "BDFB Bus High Current 2 Alarm." --#SUMMARY "BDFB Bus High Current 2 Alarm" --#SEVERITY MAJOR ::= { bdfbBusTraps 7 } -- ******** FINISH BDFB BUS ALARM TRAPS ******** END